Violation Detail
Standard Cited: 19100179 B03 Overhead and gantry cranes.
Inspection Nr: 1192516.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 05/01/2017 2
Initial Penalty: $12,548.00
Current Penalty: $12,548.00
Issuance Date: 04/05/2017
Nr Instances: 3
Nr Exposed: 15
Related Event Code (REC): A
Gravity: 10
Report ID: 0830100
Contest Date:
Final Order: 04/27/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/27/2017 | $12,548.00 | 05/01/2017 | Serious | |
| Penalty | Z: Issued | 04/05/2017 | $12,548.00 | 05/01/2017 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.179(b)(3): Crane(s) were modified and such modifications and the supporting structure were not checked thoroughly for the new rated load by a qualified engineer or the equipment manufacturer: (a) Hoist 2: On November 17, 2016 and at times prior, employees were exposed to struck by hazards while working with a JET 1 Ton manual chain hoist mounted on a fabricated structure. The employer failed to have the crane and structure assembly rated by a qualified engineer or the equipment manufacturer. (b) Hoist 22:On November 17, 2016 and at times prior, employees were exposed to struck by hazards while working with a CM Loadstar 1/2 Ton electric chain hoist mounted on a fabricated structure. The employer failed to have the crane and structure assembly rated by a qualified engineer or the equipment manufacturer. (c) Hoist 24: On November 17, 2016 and at times prior, employees were exposed to struck by hazards while working with a Chester 1 Ton manual chain hoist mounted on a fabricated structure. The employer failed to have the crane and structure assembly rated by a qualified engineer or the equipment manufacturer.
Translate