Violation Detail
Standard Cited: 19260416 A03 General requirements.
Inspection Nr: 1182926.015
Citation: 01003
Citation Type: Other
Abatement Date: 01/01/2017 2
Initial Penalty: $2,850.00
Current Penalty: $1,710.00
Issuance Date: 10/31/2016
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity:
Report ID: 0625400
Contest Date:
Final Order: 11/21/2016
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/21/2016 | $1,710.00 | 01/01/2017 | Other | |
| Penalty | Z: Issued | 10/31/2016 | $2,850.00 | 11/04/2016 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.416(a)(3): Before work began, the employer did not ascertain by inquiry, direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, was so located that the performance of the work could bring any person, tool, or machine into physical or electrical contact with the electric power circuit. On or about 8 October 2016, and at times prior thereto, the employer did not ascertain at the work site whether the electrical wire running across the culvert or pipe was energized during the performance of work, exposing the workers to an electrical hazard. Various job tools used included hand-held saws, a sledgehammer, and a wheelbarrow.