Violation Detail
Standard Cited: 19260502 B01 Fall protection systems criteria and practices.
Inspection Nr: 1171908.015
Citation: 01002
Citation Type: Serious
Abatement Date: 02/27/2017 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/14/2017
Nr Instances: 1
Nr Exposed: 5
Related Event Code (REC):
Gravity: 5
Report ID: 0418600
Contest Date:
Final Order: 03/13/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 02/14/2017 | $0.00 | 02/27/2017 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.502(b)(1): The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level: a) At Pump House Location: On or about August 22, 2016 and at times prior; the employer failed to ensure the coffer dam walls located around the pump house being used as guardrails were the proper height of 42 inches as per the standard exposing his employees to a fall hazard of 18 feet to the ground below. The height of the wall was measured at 35 inches.
Translate