Violation Detail
Standard Cited: 19100147 C01 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1101342.015
Citation: 01001
Citation Type: Serious
Abatement Date: 05/27/2016 2
Initial Penalty: $4,900.00
Current Penalty: $3,920.00
Issuance Date: 04/19/2016
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): A
Gravity: 10
Report ID: 0418200
Contest Date:
Final Order: 05/11/2016
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/11/2016 | $3,920.00 | 05/27/2016 | Serious | |
| Penalty | Z: Issued | 04/19/2016 | $4,900.00 | 05/13/2016 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a) 1226 Bankhead Highway #A, Carrollton, GA. 30116, The employer failed to establish a lockout/tagout program which consisted of energy control procedures, employee training and periodic inspections regarding servicing or maintenance on vehicles. An employee was removing a power steering gearbox from a 2001 Chevrolet Tahoe truck, (VIN 1GNEC13T31J177170), supported by two concrete blocks. The employee was crushed between the ground and the A-Frame of the vehicle, resulting in fatal injuries.