Violation Detail
Standard Cited: 19261053 B01 Ladders.
Inspection Nr: 1095056.015
Citation: 01002A
Citation Type: Serious
Abatement Date: 03/24/2016 2
Initial Penalty: $1,600.00
Current Penalty: $1,600.00
Issuance Date: 03/04/2016
Nr Instances: 1
Nr Exposed: 7
Related Event Code (REC): C
Gravity: 5
Report ID: 0830500
Contest Date:
Final Order: 04/07/2016
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 03/04/2016 | $1,600.00 | 03/24/2016 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1926.1053(b)(1): When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet above the upper landing surface to which the ladder was used to gain access: a) Excellent Exteriors Construction, LLC. at 2224 Elmira Street, Aurora, CO 80010: On and before September 29, 2015 the employer did not ensure that the portable ladder used to access the back garage roof had its ladder side rails extended at least 3 feet above the upper roof. This ladder was extended up by only one rung (one foot) in length. Condition exposed employees to a 12 foot fall hazard.