Violation Detail
Standard Cited: 19260757 E04 Open web steel joists.
Inspection Nr: 1090285.015
Citation: 01004
Citation Type: Serious
Abatement Date: 04/10/2017 2
Initial Penalty: $3,850.00
Current Penalty: $3,410.00
Issuance Date: 03/02/2016
Nr Instances: 1
Nr Exposed: 8
Related Event Code (REC):
Gravity: 5
Report ID: 0111400
Contest Date: 03/28/2016
Final Order: 05/05/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 05/05/2017 | $3,410.00 | 04/10/2017 | Serious | |
| Penalty | C: Contested | 03/31/2016 | $3,850.00 | 03/10/2016 | Serious | |
| Penalty | Z: Issued | 03/02/2016 | $3,850.00 | 03/10/2016 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1926.757(e)(4): Bundles of decking were placed on steel joists without all bridging having been installed and anchored and all joist bearing ends attached, and all of the conditions in subparagraphs (e)(4)(i) through (e)(4)(vi) were not met. Jobsite: Bays between column lines 4 and 5. Bundles of decking were placed on steel joists when the joists had not been bridged in accordance with the steel erection drawings. The site specific steel erection plan had no documentation that a qualified person had determined that it was safe to place decking on steel joists without joists being fully bridged and in at least 2 bays decking was placed more than 1 foot of the bearing surface of the joist end.
Translate