Violation Detail
Standard Cited: 19260757 D02 II Open web steel joists.
This violation item has been deleted.
Inspection Nr: 1090285.015
Citation: 01003A
Citation Type: Serious
Abatement Date: 03/10/2016 2
Initial Penalty: $3,850.00
Current Penalty: $0.00
Issuance Date: 03/02/2016
Nr Instances: 1
Nr Exposed: 11
Related Event Code (REC):
Gravity: 5
Report ID: 0111400
Contest Date: 03/28/2016
Final Order: 05/05/2017
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 05/05/2017 | $0.00 | 03/10/2016 | Serious | |
| Penalty | C: Contested | 03/31/2016 | $3,850.00 | 03/10/2016 | Serious | |
| Penalty | Z: Issued | 03/02/2016 | $3,850.00 | 03/10/2016 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1926.757(d)(2)(ii): Two rows of bolted diagonal erection bridging were not installed near the third points of steel joists more than 60 feet long. Jobsite: Bays between Columns 4 and 5. Only one row of diagonal erection bridging was installed on most steel joists more than 60 feet long and that bridging was near the center of the joist span. No diagonal erection bridging was installed one of the steel joists.