Violation Detail
Standard Cited: 19260552 C15 Material hoists, personnel hoists, and elevators.
Inspection Nr: 1090116.015
Citation: 01003
Citation Type: Serious
Abatement Date: 02/11/2016 2
Initial Penalty: $7,000.00
Current Penalty: $7,000.00
Issuance Date: 02/04/2016
Nr Instances: 1
Nr Exposed: 11
Related Event Code (REC):
Gravity: 10
Report ID: 0936200
Contest Date: 02/24/2016
Final Order: 11/04/2016
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 11/04/2016 | $7,000.00 | 02/11/2016 | Serious | |
| Penalty | C: Contested | 03/17/2016 | $7,000.00 | 02/11/2016 | Serious | |
| Penalty | Z: Issued | 02/04/2016 | $7,000.00 | 02/11/2016 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.552(c)(15): Personnel hoists were not inspected and tested of all functions and safety devices at not more than 3-month intervals; and a certification record was not maintained or available for review that included the date(s) of the inspection and test, the signature of the person who performed the inspection and test, and the serial number or other identifier of the hoist that was inspected: On or about September 1, 2015, the employer did not inspect and test all functions and safety devices of the Alimak FC 7100-12D hoist at the site at not more than 3-month intervals; and did not maintain a certification record documenting the test of all safety functions and safety devices on the hoist since initial certification on March 28, 2015 by the competent Morrow Crane technician.