Violation Detail
Standard Cited: 19100218 A03 VIII Forging machines.
Inspection Nr: 106940.015
Citation: 01004
Citation Type: Serious
Abatement Date: 04/20/2012 2
Initial Penalty: $3,000.00
Current Penalty: $3,000.00
Issuance Date: 03/21/2012
Nr Instances: 1
Nr Exposed: 11
Related Event Code (REC):
Gravity: 5
Report ID: 0521400
Contest Date:
Final Order: 04/05/2012
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/05/2012 | $3,000.00 | 04/20/2012 | Serious | |
| Penalty | Z: Issued | 03/21/2012 | $3,000.00 | 04/20/2012 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.218(a)(3)(viii): Scale guards of substantial construction, arranged to stop flying scale, were not provided at the back of forging hammer(s): Scale guards made of sheet metal and used at the back of forging hammers were not adequate to prevent employees from being struck by hot, flying scale. One of the scale guards had a large vertical separation in it. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).