Violation Detail
Standard Cited: 19261053 B01 Ladders.
Inspection Nr: 1064868.015
Citation: 01002
Citation Type: Serious
Abatement Date: 06/03/2015 2
Initial Penalty: $2,000.00
Current Penalty: $1,200.00
Issuance Date: 05/26/2015
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0111100
Contest Date:
Final Order: 06/12/2015
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/12/2015 | $1,200.00 | 06/03/2015 | Serious | |
| Penalty | Z: Issued | 05/26/2015 | $2,000.00 | 06/03/2015 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: Penury Hall - The aluminum extension ladder was not extended 3 feet above the roof surface.
Translate