Violation Detail
Standard Cited: 19280051 B02 I B Roll-over protective structures (ROPS) for tractors used in agricultural op...
Inspection Nr: 1061669.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 08/17/2015 2
Initial Penalty: $2,800.00
Current Penalty: $2,800.00
Issuance Date: 07/22/2015
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC): A
Gravity: 10
Report ID: 0830100
Contest Date:
Final Order: 08/12/2015
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/12/2015 | $2,800.00 | 08/17/2015 | Serious | |
| Penalty | Z: Issued | 07/22/2015 | $2,800.00 | 08/17/2015 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1928.51(b)(2)(i)(B): Where ROPS were required by this section, the employer did not ensure that each employee tightened the seatbelt sufficiently to confine the employee to the protected area provided by the ROPS: (a) John Erb Ranch: On or about April 25th, 2015 and at times prior, employees were exposed to struck by hazards while feeding cattle in an overloaded John Deere 6140M tractor.