Violation Detail
Standard Cited: 19100252 A03 II General requirements.
Inspection Nr: 1061177.015
Citation: 01002B
Citation Type: Serious
Abatement Date: 07/07/2015 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/12/2015
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): R
Gravity: 10
Report ID: 0213600
Contest Date:
Final Order: 06/30/2015
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/30/2015 | $0.00 | 07/07/2015 | Serious | |
| Penalty | Z: Issued | 06/12/2015 | $0.00 | 07/07/2015 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.252(a)(3)(ii): All hollow spaces, cavities, or containers were not vented to permit the escape of air or gases before preheating, cutting, or welding was performed: a) On or about 05/04/2015 in the torching area; where torch cutting of wire cable on top of a closed vessel, that contained combustible/flammable residue, resulted in a flash fire which burned the employee performing the torch cutting. ABATEMENT DOCUMENTATION REQUIRED