Violation Detail
Standard Cited: 19260502 K01 Fall protection systems criteria and practices.
Inspection Nr: 1060048.015
Citation: 01002
Citation Type: Serious
Abatement Date: 05/14/2015 2
Initial Penalty: $2,800.00
Current Penalty: $1,400.00
Issuance Date: 05/06/2015
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 10
Report ID: 0111100
Contest Date:
Final Order: 06/01/2015
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/01/2015 | $1,400.00 | 05/14/2015 | Serious | |
| Penalty | Z: Issued | 05/06/2015 | $2,800.00 | 05/14/2015 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.502(k)(1): 29 CFR 1926.502(k): The fall protection plan did not conform to the provisions specified in 1926.502(k)(1) through (k)(10): Job Site - The fall protection plan did not conform to the following provisions specified in 1926.502(k) during sheathing operations: a) Section 1: The fall protection plan was not specific to the job site. b) Section 3: A copy of the fall protection plan was not on site. c) Section 6: The plan did not include other measures to take in order to reduce or eliminate fall hazards such as scaffolds or vehicle mounted work platforms. d) Section 7: Controlled access zones were not identified. e) Section 8: A safety monitoring system had not been implemented were no other alternative measure had been implemented. f) Section 9: The plan did not provide the names of employees designated to work in the controlled access zones.