Violation Detail
Standard Cited: 19261417 C01
Inspection Nr: 1057593.015
Citation: 01006
Citation Type: Serious
Abatement Date: 10/26/2015 2
Initial Penalty: $7,000.00
Current Penalty: $4,900.00
Issuance Date: 10/14/2015
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0215800
Contest Date:
Final Order: 11/05/2015
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/05/2015 | $4,900.00 | 10/26/2015 | Serious | |
| Penalty | Z: Issued | 10/14/2015 | $7,000.00 | 10/26/2015 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1926.1417(c)(1): The procedures applicable to the operation of the equipment, including rated capacities (load charts), recommended operating speeds, special hazard warnings, instructions, and operator's manual, were not readily available at all times for use by the operator: a) On or about 4/21/2015, In front of 5231 Coye Road and various other delivery sites: An International Boom truck with a Palfinger Hydraulic Boom was not equipped with load charts, operators manual, and legibly labeled operating controls. Abatement certification is required for this item.
Translate