Violation Detail
Standard Cited: 19261412 D01
Inspection Nr: 1057593.015
Citation: 01004A
Citation Type: Serious
Abatement Date: 10/26/2015 2
Initial Penalty: $7,000.00
Current Penalty: $4,900.00
Issuance Date: 10/14/2015
Nr Instances: 2
Nr Exposed: 2
Related Event Code (REC): A
Gravity: 5
Report ID: 0215800
Contest Date:
Final Order: 11/05/2015
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/05/2015 | $4,900.00 | 10/26/2015 | Serious | |
| Penalty | Z: Issued | 10/14/2015 | $7,000.00 | 10/26/2015 | Serious |
Text For Citation: 01 Item/Group: 004A Hazard:
29 CFR 1926.1412(d)(1): Visual inspections were not performed by a competent person prior to each shift for apparent deficiencies of the equipment that was used: a) On or about 4/21/2015, In front of 5231 Coye Road and other job sites: International Boom trucks with Palfinger Hydraulic Booms were not visually inspected prior to daily operations. Items such as, but not limited to, proper functioning of the controls were not inspected. Abatement certification is required for this item.
Translate