Violation Detail
Standard Cited: 19261431 P02
Inspection Nr: 1043003.015
Citation: 01004
Citation Type: Serious
Abatement Date: 03/18/2015 2
Initial Penalty: $2,200.00
Current Penalty: $1,100.00
Issuance Date: 03/06/2015
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 1032100
Contest Date:
Final Order: 03/31/2015
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/31/2015 | $1,100.00 | 03/18/2015 | Serious | |
| Penalty | Z: Issued | 03/06/2015 | $2,200.00 | 03/18/2015 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1926.1431(p)(2): For lattice boom cranes: The cable was not clearly marked (so that it could easily be seen by the operator) at a point that will give the operator sufficient time to stop the hoist to prevent two-blocking, or a spotter was not used who was in direct communication with the operator to inform the operator when this point is reached. Aurora Harbor, Barge CP 39, Manitowoc Model 4000W: On or about February 25, 2015 and at times prior thereto, while hoisting personnel, the cable was not clearly marked to prevent two-blocking. This condition exposed employees to struck-by and fall hazards in the event of two-blocking.