Violation Detail
Standard Cited: 19260451 C01 General requirements.
Inspection Nr: 1015985.015
Citation: 01002
Citation Type: Serious
Abatement Date: 07/08/2015 7
Initial Penalty: $2,800.00
Current Penalty: $2,800.00
Issuance Date: 06/25/2015
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC):
Gravity: 10
Report ID: 0524200
Contest Date:
Final Order: 07/27/2015
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 06/25/2015 | $2,800.00 | 07/08/2015 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.451(c)(1): Supported scaffold(s) with a height to base width (including outrigger supports) ratio greater than four to one (4:1) was not restrained from tipping by guying, tying, bracing, or equivalent means: a) On or about December 30, 2014, employees were exposed to fall hazards of greater than 25 feet while working on a tubular welded frame scaffold which was not restrained from tipping by any means. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Translate