Violation Detail
Standard Cited: 19100212 A05 General requirements for all machines.
Inspection Nr: 1013762.015
Citation: 01004
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $3,300.00
Current Penalty: $1,980.00
Issuance Date: 05/29/2015
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC):
Gravity: 1
Report ID: 0418500
Contest Date:
Final Order: 06/19/2015
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/19/2015 | $1,980.00 | Serious | ||
Penalty | Z: Issued | 05/29/2015 | $3,300.00 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch: a) South wall of the Fuel Maintenance Store Room: A job made wall/window fan 5 feet, 5 inches from the concrete floor had a fan blade guard with 2 inch openings.