Powered by GoogleTranslate

Violation Detail

Standard Cited: 19100106 E06 I Flammable liquids.

Inspection Nr: 1011328.015

Citation: 01001

Citation Type: Serious

Abatement Status: Abatement Completed

Initial Penalty: $7,000.00

Current Penalty: $7,000.00

Issuance Date: 03/30/2015

Nr Instances: 1

Nr Exposed: 2

Abatement Date: 05/02/2015

Gravity: 10

Report ID: 0317700

Contest Date:

Final Order: 04/23/2015

Related Event Code (REC): A

Emphasis:

Substance: 2460


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 04/23/2015 $7,000.00 05/02/2015 Serious  
Penalty Z: Issued 03/30/2015 $7,000.00 05/02/2015 Serious  

Text For Citation: 01 Item/Group: 001 Hazard:

29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors from sources such as open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat: a) Day Mix Room: Employees poured a metal bucket that contained a liquid toluene/resin mix directly into the Day mixing tank that contained approximately 70 gallons of the flammable liquid, toluene. The employer did not ensure that the metal bucket was bonded and/or grounded to prevent static discharge during the pouring of this liquid mixture, on or about 12/3/2014. b) Day Mix Room: Employees poured/dumped liquid and solid chemicals directly into the Day mixing tank that contained approximately 70 gallons of the flammable liquid, toluene. The employer did not ensure that employees wore the available anti-static wrist grounding straps and/or other static control mechanisms (e.g., static dissipative footwear, anti-static or conductive clothing) to prevent static discharge from the body. The employer did not ensure that the metal grounding plugs on the available anti-static wrist grounding straps were free from an accumulation of residue that would prevent successful metal to metal grounding, on or about 12/3/2014. c) Day Mix Room: Employees dumped non-conductive cardboard boxes and non-conductive paper bags that contained solid bulk and powdered chemicals directly into the Day mixing tank that contained approximately 70 gallons of the flammable liquid, toluene. The employer did not ensure that employees used the available intermediate chemical load chute, with attached nitrogen inerting, on the Day mixer tank opening, to eliminate the explosive toluene vapors and prevent the ignition of flammable vapors, on or about 12/3/2014. d) Day Mix Room: Employees poured/dumped liquid and solid chemicals directly into the Day mixing tank that contained approximately 70 gallons of the flammable liquid, toluene. The employer did not ensure that employees turned on the valve that provided nitrogen to inert the headspace of the Day mixer tank and chemical load chute, prior to chemical additions to the day mixer, to eliminate the explosive toluene vapors and prevent the ignition of flammable vapors, on or about 12/3/2014. ABATEMENT CERTIFICATION REQUIRED

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close