Violation Detail
Standard Cited: 19260451 E01 General requirements.
Inspection Nr: 1005580.015
Citation: 01002
Citation Type: Serious
Abatement Date: 11/20/2014 2
Initial Penalty: $2,800.00
Current Penalty: $1,600.00
Issuance Date: 11/12/2014
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 10
Report ID: 0418600
Contest Date:
Final Order: 12/02/2014
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/02/2014 | $1,600.00 | 11/20/2014 | Serious | |
| Penalty | Z: Issued | 11/12/2014 | $2,800.00 | 11/20/2014 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used: a) At 1956 West Beach Blvd, Gulf Shores, Al; On or about October 29, 2014 and times prior: The employer failed to ensure employees were provided with proper access to the working platforms in that they climbed out a second story window which was more than 2 feet below the platform which exposed them to the hazards associated with falls of up to 17 feet 5 inches to the ground below.