Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1264719.015
Citation: 01007B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/09/2018
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 05/14/2018
Gravity: 10
Report ID: 0336000
Contest Date:
Final Order: 03/22/2018
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/22/2018 | $0.00 | 05/14/2018 | Serious | |
| Penalty | Z: Issued | 03/09/2018 | $0.00 | 04/04/2018 | Serious |
Text For Citation: 01 Item/Group: 007B Hazard:
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): A.) Barrett Farm Supply, Inc., dba Red Bank Mills - On or about 9/12/17, and at times prior thereto, employees were performing servicing and maintenance on equipment that included, but was not limited to, the corn cracker. The equipment was not being locked out prior to work being performed.