Violation Detail
Standard Cited: 19100107 C09 I Spray finishing using flammable and combustible materials.
Inspection Nr: 1466507.015
Citation: 01005
Citation Type: Serious
Abatement Date: 10/19/2020 2
Initial Penalty: $6,747.00
Current Penalty: $2,800.00
Issuance Date: 08/31/2020
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0112000
Contest Date:
Final Order: 09/28/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/28/2020 | $2,800.00 | 10/19/2020 | Serious | |
Penalty | Z: Issued | 08/31/2020 | $6,747.00 | 10/19/2020 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.107(c)(9)(i): All metal parts of piping systems conveying flammable or combustible liquids were not properly electrically grounded in an effective and permanent manner: ADHESIVE SPRAY AREA: On or about and at times prior to March 12, 2020, a 55-gallon steel drum of 3M PB938 High Performance Spray Adhesive, a Category 2 flammable liquid with a flashpoint of -4 deg F and a boiling point of 133 deg F was not grounded. The adhesive was transferred from the drum through a pump to a spray nozzle for spraying onto wooden boards.