Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1264719.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $2,772.00
Current Penalty: $2,000.00
Issuance Date: 03/09/2018
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 04/04/2018
Gravity: 5
Report ID: 0336000
Contest Date:
Final Order: 03/22/2018
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/22/2018 | $2,000.00 | 04/04/2018 | Serious | |
| Penalty | Z: Issued | 03/09/2018 | $2,772.00 | 04/04/2018 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): A.) Barrett Farm Supply Inc., dba Red Bank Mills; mixer belt - On or about 9/19/17, and at times prior thereto, a belt/pulley was not guarded for the mixer belt located 4 ft from the floor. B.) Barrett Farm Supply Inc., dba Red Bank Mills; corn cracker belt - On or about 9/19/17, and at times prior thereto, a belt/pulley was not guarded for the corn cracker which was located 4 ft from the floor.