Violation Detail
Standard Cited: 19260501 B04 I Duty to have fall protection.
Inspection Nr: 1394531.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Not Completed - AD Discretion
Initial Penalty: $11,366.00
Current Penalty: $11,366.00
Issuance Date: 06/19/2019
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 07/09/2019
Gravity: 5
Report ID: 0316400
Contest Date:
Final Order: 07/17/2019
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 06/19/2019 | $11,366.00 | 07/09/2019 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes: (a) Roof of Horse Stable: On April 10, 2019 and times prior, employees were exposed to a fall of approximately 13 feet from the roof through holes approximately 38 inches wide by 78 inches in length while installing and removing metal roofing panels and skylights.
Translate