Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1043214.015
Citation: 01001
Citation Type: Repeat
Abatement Status: Abatement Completed
Initial Penalty: $22,000.00
Current Penalty: $13,200.00
Issuance Date: 06/17/2015
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 08/07/2015
Gravity: 5
Report ID: 0523900
Contest Date:
Final Order: 07/14/2015
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/14/2015 | $13,200.00 | 08/07/2015 | Repeat | |
| Penalty | Z: Issued | 06/17/2015 | $22,000.00 | 07/09/2015 | Repeat |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Floor; maintenance tasks such as but not limited to replacing bearings on DCBS 990 Series letter sorting machines, machine nos. 4 and 6, are performed without powering down and locking out the machine. The U.S. Postal Service was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(d)(4)(i), which was contained in OSHA inspection number 974268, citation number 1, item number 1 and was affirmed as a final order on October 28, 2014, with respect to a workplace located at 3232 Denmark Ave., Eagan, MN.
Translate