Inspection Detail
Inspection: 125775098 - Fryer Roofing
Inspection Information - Office: Fresno District Office
Site Address:
Fryer Roofing
7104 N. Fresno St.
Herndon, CA 93710
Mailing Address:
438 Tealman, Fresno, CA 93706
Union Status: Union
SIC:1761
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/30/1997
Emphasis:
Case Closed: 10/30/1997
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362049918 |
Investigation Summary
Employee #1, an experienced Class 5 roofer apprentice, was part of a crew preparing a roof for tar application. He was working on the tar kettle and went down, without permission, to check its temperature and before the crew was ready for it. After checking the temperature and tar level, Employee #1 started the pump. He failed, however, to check the connection of the tar delivery pipe above his head. Hot tar sprayed out of the pipe and onto Employee #1's face, neck, shoulder, back, and hands. He sustained second-degree burns to his upper body, for which he was hospitalized.
Keywords: BURN, SHOULDER, UNSECURED, WORK RULES, CONSTRUCTION, LINE CONNECTOR, ROOFER, FACE, HOT TAR, ACCIDENTAL DISCHARGE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 125775098 | Hospitalized injury | Burn/Scald(Heat) | Construction laborers |