Inspection Detail
Inspection: 122207194 - Generac Power Systems, Inc.
Inspection Information - Office: Milwaukee Area Office
Site Address:
Generac Power Systems, Inc.
211 Murphy Dr.
Eagle, WI 53119
Mailing Address:
P.O.Box 8, Eagle, WI 53119
Union Status: Union
SIC:3444
NAICS: 0
Inspection Type: Complaint
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/02/1998
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 12/04/1998
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 200121044 | Yes | |
| Complaint | 200120939 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $4,500 | $0 | $0 | $0 | $0 | $4,500 |
| Current Penalty | $2,250 | $0 | $0 | $0 | $0 | $2,250 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19100212 A01 | 07/02/1998 | 08/19/1998 | $2,250 | $4,500 | $0 | 07/23/1998 | F - Formal Settlement | |
| 2. | 01001B | Other | 19100212 A03 II | 07/02/1998 | 08/19/1998 | $0 | $0 | $0 | 07/23/1998 | F - Formal Settlement |
Translate