Inspection Detail
Inspection: 112045166 - Aurci
Inspection Information - Office: San Bernardino District Office
Site Address:
Aurci
1841 Hillside Ave
Norco, CA 91760
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:2813
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/07/1992
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 10/23/1992
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 361339435 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | 2 | |||
Current Violations | 1 | 1 | ||||
Initial Penalty | $2,000 | $0 | $0 | $2,000 | $0 | $4,000 |
Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 460 A | 02/18/1992 | 02/18/1992 | $0 | $2,000 | $0 | W - Empr Withdrew | Citation has been deleted. | |
2. | 02001 | Other | 3203 A | 02/18/1992 | 02/18/1992 | $0 | $2,000 | $0 | 03/16/1992 | W - Empr Withdrew |
Investigation Summary
Employee #1, of Airco, was transferring liquid nitrogen from his truck to a 1,400 gal spherical tank. The tank exploded and Employee #1 suffered the loss of his right eye, the partial loss of his right jaw, and other facial injuries. The tank was not approved by ANCE.
Keywords: EYE, WORK RULES, NITROGEN, EXPLOSION, STRUCK BY, FACE, TANK, EQUIPMENT APPROVAL
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 112045166 | Hospitalized injury | Other | Occupation not reported |