Inspection Detail
Inspection: 108954850 - Anacomp, Inc.
Inspection Information - Office: Birmingham Area Office
Site Address:
Anacomp, Inc.
112 Walter Davis Dr.
Birmingham, AL 35209
Mailing Address:
229 Roebuck Plaza Dr. Suite 103, Birmingham, AL 35206
Union Status: NonUnion
SIC:7334
NAICS: 0
Inspection Type: Unprog Rel
Scope: Partial
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 10/22/1992
Emphasis:
Case Closed: 11/03/1992
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360792329 |
Investigation Summary
AN EMPLOYEE WAS REPLACING THE ULTRAVIOLET EXPOSURE LAMP ON A MICROFICHE DUPLICATING MACHINE. HE DID NOT OPEN THE DISCONNECTING MEANS FOR THE MACHINE BEFORE OPENING THE CABINET ACCESS DOORS. HE APPARENTLY CONTACTED EXPOSED ENERGIZED PARTS AND WAS ELECTROCUTED.
Keywords: E GI IV, ELECTRICAL, UNTRAINED, ELECTROCUTED, ELECTRICAL WORK, INTERLOCK, LOCKOUT, ELEC CIRC PART--MISC, ELEC EQUIPMENT--MISC
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 108954850 | Occupation Not Listed |