Inspection Detail
Inspection: 101965218 - Cox Manufacturing Co., Inc.
Inspection Information - Office: Indiana
Site Address:
Cox Manufacturing Co., Inc.
108 W. 2nd St.
Ridgeville, IN 47380
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3585
NAICS: 0
Inspection Type: Planned
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/25/1986
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 02/02/1987
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 3 | 4 | |||
Current Violations | 1 | 3 | 4 | |||
Initial Penalty | $240 | $0 | $0 | $0 | $0 | $240 |
Current Penalty | $120 | $0 | $0 | $0 | $0 | $120 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001A | Serious | 19100217 C01 I | 07/16/1986 | 08/18/1986 | $120 | $240 | $0 | 08/21/1986 | F - Formal Settlement | |
2. | 01001B | Serious | 19100217 B03 I | 07/16/1986 | 08/18/1986 | $0 | $0 | $0 | 08/21/1986 | - | |
3. | 02001 | Other | 19100217 E01 I | 07/16/1986 | 08/18/1986 | $0 | $0 | $0 | 08/21/1986 | - | |
4. | 02002 | Other | 19100217 E01 II | 07/16/1986 | 08/18/1986 | $0 | $0 | $0 | 08/21/1986 | - | |
5. | 02003 | Other | 19101200 E01 | 07/16/1986 | 08/18/1986 | $0 | $0 | $0 | 08/21/1986 | - |
Investigation Summary
At approximately 2:30 p.m. on May 30, 1986, Employee #1 was used his fingers to place a 2 1/2 inch diameter part disc on the curve of the lower die in a 15 ton Federal full revolution mechanical power press. The dog that engages the flywheel broke, letting the press run continuously. There were approximately 2 inches between the upper die and the part. The upper die came down on his thumb, pinning it. The part did not set in the lower die, allowing the operator time to recut and pull his thumb out. He sustained a skinned thumb, loss of the nail, and mangled skin on the end of the thumb. He was hospitalized for treatment. The press was being used without a point of operation guard and no single control mechanism.
Keywords:die, power press, pinned, work rules, thumb, caught between, press, unguarded
# | Inspection | Age | Sex | Degree | Nature | Occupation |
---|---|---|---|---|---|---|
1 | 101965218 | Hospitalized injury | Bruise/Contus/Abras | Physician's assistants |