Accident Report Detail
Accident Summary Nr: 951145 - EMPLOYEE KILLED IN FALL WHEN AERIAL LIFT FAILED
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 126638949 | 04/14/1997 | 0783 | 0 | Stackhouse, Inc. |
Abstract: An employee was working from an aerial lift, trimming trees from an overhead power line. He was elevated about 12.2 meters above the ground when the boom of the aerial lift failed, causing the bucket to fall to the ground. The employee sustained acute chest injuries that resulted in his death. The cause of the boom failure was determined to be metal fatigue.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 126638949 | Fatality | Fracture | Forestry workers, except logging |
Accident Summary Nr: 200200137 - EMPLOYEE KILLED IN FAILURE OF AERIAL LIFT BOOM
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 300172061 | 08/22/1996 | 0783 | 0 | Thompson Contracting, Inc. |
Abstract: An employee was in an aerial lift performing a line-clearance tree-trimming operation near a residential overhead power line. A cable on the joint of the articulating-arm boom failed, causing the boom to collapse. The bucket swung into the lift arm and struck the employee on the head. He was killed.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300172061 | Fatality | Bruise/Contus/Abras | Forestry workers, except logging |
Accident Summary Nr: 928168 - EMPLOYEE KILLED IN FAILURE OF AERIAL LIFT BOOM
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 109674242 | 02/09/1996 | 0783 | 0 | Burford'S Tree, Inc. |
Abstract: A tree trimmer was in an aerial lift performing a line-clearance operation. He was in the bucket of the aerial lift about 6.7 meters above the ground, using a pole cutter to trim the trees. As he was adjusting the bucket, the hydraulic cylinder for the lower boom failed when the rod pulled through the locking assembly nut. A total loss of hydraulic fluid caused the extended boom and bucket to free-fall to the ground, killing the employee.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 109674242 | Fatality | Other | Forestry workers, except logging |
Accident Summary Nr: 908343 - FALL - AERIAL LIFT BOOM FAILURE
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 124675307 | 02/09/1995 | 1623 | 0 | Floyd S. Pike Electrical Contractor, Inc. |
Abstract: Two employees were working from an aerial lift bucket, upgrading a two-phase overhead power line to a three-phase line. The boom failed, and the bucket fell 30 feet to the ground. One of the employees sustained a contusion on his hip; the other sustained a contusion on his chest.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 124675307 | Non Hospitalized injury | Bruise/Contus/Abras | Electrical power installers and repairers | ||
| 2 | 124675307 | Non Hospitalized injury | Bruise/Contus/Abras | Electrical power installers and repairers |
Accident Summary Nr: 837740 - FALL - AERIAL LIFT FAILURE
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 103378683 | 09/26/1994 | 1623 | 0 | Henkels & Mccoy, Inc. |
Abstract: An employee was descending in a Hi-Ranger articulating-boom aerial lift after working on a utility pole. He was not using personal fall arrest or restraint equipment. The compensating chain installed in the base section of the aerial lift broke, causing the upper boom section to free-fall. This section struck the saddle of the lower section and threw the employee headfirst out of the bucket and onto the paved street. He was air lifted to a local hospital and pronounced dead on arrival of massive head injuries.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 103378683 | Fatality | Fracture | Electrical power installers and repairers |
Accident Summary Nr: 14244818 - FALL - AERIAL LIFT FAILURE
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 17710518 | 04/08/1994 | 1731 | 0 | Bell Of Pennsylvania |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 17710484 | 04/08/1994 | 1731 | 0 | Alfred J. Fry 3rd Electrical Construction |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 17710500 | 04/14/1994 | 1623 | 0 | Peco Energy Company |
Abstract: A power line worker was in an aerial lift bucket, lowering the boom back into the truck bed. A cable on the aerial lift had broken. When a second cable broke, the boom fell freely, causing the employee to fall out of the bucket. The employee, who was not using fall protection equipment, was killed.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 17710518 | Occupation Not Listed | ||||
| 2 | 17710484 | Fatality | Fracture | Electrical power installers and repairers | ||
| 3 | 17710500 | Occupation Not Listed |
Accident Summary Nr: 564765 - EMPLOYEE FELL WHEN AERIAL LIFT BOOM FAILED
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 107572570 | 01/15/1992 | 7359 | 0 | Uec Equipment Company |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 107572596 | 01/15/1992 | 4911 | 0 | Southwest Arkansas Electric Coop. |
Abstract: An employee had finished making repairs and adjustments on an aerial lift and was making a test run. During this test, a nut on the lower hydraulic cylinder shaft broke into two pieces, causing the bucket and boom to fall 6.1 to 7.6 meters. The employee fell from the bucket onto the concrete, resulting in his death.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 107572570 | Fatality | Fracture | Not specified mechanics and repairers | ||
| 2 | 107572596 | Occupation Not Listed |