Accident Report Detail
Accident Summary Nr: 202544268 - Employee Face Struck by a Broken Grinder Blade
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 314861626 | 05/09/2012 | 1743 | 238340 | G&H Marble |
Abstract: At approximately 3:00 a.m. on May 3, 2012, Employee #1 of G&H Marble was injured. Employee #1 was using a 5" Makita Grinder (9565 CV, serial number: 76743 A) to cut a slab of marble. The cutting blade broke and the broken pieces seriously injured Employee #1's left eye and face. Two employees were installing counter top for Panda Express restaurant located inside a mall. At the time of accident, the grinder Employee #1 used had no safety guard. Employee #1 was not provided personal protection equipment such as goggles or face shield. Employer had no IIPP, did not inspect the grinder periodically and did not provide training to employees.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Commercial building | Maintenance or repair | Under $50,000 | 1 | 20 | |||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 314861626 | Hospitalized injury | Foreign Body Ineye | Construction laborers |