Accident Summary Nr: 202506382 - Employee Sustains Thermal Burns
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 311068761 | 01/31/2008 | 2869 | 325193 | Pacific Ethanol, Inc. |
Abstract: At approximately 10:21 a.m. on November 16, 2007, Employee #1 was pressure washing trays located inside the beer column located at the corner of the plant. The beer column is considered a confined space and two attendants and a safety coordinator were near the beer column at the time of the accident. While Employee #1 was inside of the beer column, the boilers remained operational and maintained steam pressure in the system at approximately 100 psi. The manual steam blocker valve was not in the closed position and steam bypassed the manual steam blocker valve and the steam control valve. The steam heated the water in the beer feed preheater, causing boiling water to travel through the beer feed line into the beer column. Employee #1 was inside the beer column and sustained burns to his face, bilateral upper extremities, and back. Employee #1 was hospitalized.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 311068761 | Hospitalized injury | Burn/Scald(Heat) | Managers and administrators, n.e.c |