Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 202469565 - Employee Is Killed When Trench Caves- In

Accident Summary Nr: 202469565 -- Report ID: 0950643 -- Event Date: 02/08/2011
Inspection NrDate OpenedSICNAICSEstablishment Name
31482355002/08/20111542236220Pacific Edge Real Estate

Abstract: At approximately 3:00 p.m. on February 08, 2011, Employee #1 was working for his employer, Pacific Edge Real Estate as a laborer. Employee # 1 was hand excavating in the trench that was approximately 2 ft. wide by 12 ft. long by 65 inches deep. The side of the trench collapsed and Employee # 1 was buried in the dirt up to his neck. Employee # 1 was transported to Los Angeles County Coroner. The accident was reported to the Division on February 8, 2011. The trench did not have a protective system.

Keywords: EXCAVATION, COLLAPSE, TRENCH, BURIED, CAVE-IN
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Single family or duplex dwelling New project or new addition $250,000 to $500,000 2 35 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 314823550 Fatality Bruise/Contus/Abras Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Excavation
Fatality Cause: Collapse of structure

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.