Accident Report Detail
Accident Summary Nr: 202442927 - Employee's Thumb Amputated by Saw
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 125881888 | 01/13/2006 | 1521 | 236118 | W Hoffmann Construction |
Abstract: At approximately 3:15 p.m. on December 20, 2005, Employee #1, a carpenter, was holding an 18-in. by 2-in. by 4-in. board with his left hand and was rip cutting it with a Makita hypoid drive circular saw. He was steadying the board by placing its far-end of the board on the ground. The saw jammed, kicked back, struck and amputated his left thumb. Employee #1 was transported to a local medical facility and then flown by helicopter to USC Medical Center in Los Angeles for surgery. The blade guard was operating correctly and not pinned back. Employee #1 was not hospitalized.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Single family or duplex dwelling | Alteration or rehabilitation | $250,000 to $500,000 | 2 | ||||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 125881888 | Non Hospitalized injury | Amputation | Carpenter apprentices | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Interior carpentry Fatality Cause: Other |