Accident Report Detail
Accident Summary Nr: 202330338 - Crane boom damaged in tip over
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 304566482 | 07/12/2001 | 1611 | 0 | George & Lynch, Inc. |
Abstract: Employees were pouring an abutment for an overpass when the crane that they were using tipped over. The crane operator was picking a wooden bulkhead weighing approximately 100 lb that was positioned in the center of the abutment. The pick was made and the boom swung around from west to east. When the boom reached the point at which it was perpendicular to the crane, the weight of the extended boom was too great for the crane, without having the outriggers extended on that side, causing the crane to tip over. There was approximately 65 feet of boom extended. There were no serious injuries to employees, however, there was damage sustained to the boom of the crane.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Highway, road, street | New project or new addition | $20,000,000 and over | |||||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 304566482 | Non Hospitalized injury | Other | Crane and tower operators | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Forming Fatality Cause: Lifting operations |