Accident Summary Nr: 202311783 - Employee Loses Finger In Punch Machine
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 119685196 | 05/03/1999 | 3499 | 0 | Williams, Mfg Corp |
Abstract: Employee #1, an experienced punch press machine operator, lost one finger and broke another when he failed to use the provided pull backs on a Bliss punch press. He was loading a part on the press with his left hand, operating the press with his foot, and removing a part from the press with his right hand. His rhythm became out of sync, and his hand was still in the press as his foot activated the press. As a result, one finger was amputated and another finger was broken. He failed to use the pull backs to stop the press. He went to a local hospital for treatments.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 119685196 | Hospitalized injury | Amputation | Punching and stamping press machine operators |