Accident Summary Nr: 202013090 - Employee buried in trench collapse

Accident Summary Nr: 202013090 -- Report ID: 0216000 -- Event Date: 09/26/1998
Inspection NrDate OpenedSICNAICSEstablishment Name
30146008509/28/199817940Eastern Excavation, Inc.

Abstract: Employee #1 and another employee were working inside a trench box. The area being excavated was approximately 40 ft long, 6.5 ft wide, and 12 ft deep. The trench box was 6 ft high, 8 ft long, and 4.7 ft wide. The trenched collapsed resulting in Employee #1 being buried beneath the dirt where he died of asphyxia.

Keywords: ASPHYXIATED, COLLAPSE, TRENCH
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Highway, road, street New project or new addition Under $50,000 12 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 301460085 Fatality Asphyxia Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Trenching, installing pipe
Fatality Cause: Trench collapse

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.