Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200670974 - electric shock - contact with overhead line thru metal tape

Accident Summary Nr: 200670974 -- Report ID: 0418800 -- Event Date: 01/07/1998
Inspection NrDate OpenedSICNAICSEstablishment Name
30049653601/08/199817610Et Plastering Inc

Abstract: An employee was working on a swing stage. As he was measuring a wall, the wind blew his measuring tape backwards into an overhead power line. The employee was electrocuted.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, MEASURING DEVICE, ELECTROCUTED, E C
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building New project or new addition $500,000 to $1,000,000 1 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 300496536 Fatality Electric Shock Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Exterior masonry
Fatality Cause: Electrocution by equipment contacting wire

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.