Accident Report Detail
Accident Summary Nr: 170812630 - Employee injured when struck by falling pick-up head
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 119800118 | 07/30/1997 | 2752 | 0 | Merced Color Press Dba World Color |
Abstract: On February 10, 1997, Employee #1 was using a robotic pick-up head, in manual mode, to place a bundle of telephone directory pages on a pallet. The bundle was not properly strapped, so once it was on the pallet Employee #1 raised the pick-up head to the 'stopped' position and bent over the pallet to realign it. As he was doing, this the cogged belt that controlled the pick-up head's vertical movement broke. The pick-up head fell, striking Employee #1 on the head, neck, shoulders, and back.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 119800118 | Hospitalized injury | Other | Miscellaneous printing machine operators |