Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170741029 - ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

Accident Summary Nr: 170741029 -- Report ID: 0418100 -- Event Date: 05/09/1994
Inspection NrDate OpenedSICNAICSEstablishment Name
10651218905/09/199417710A J Concrete Pumping, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
10651219705/09/199415420The Flagler Company

Abstract: A concrete pump truck operator was moving the boom on his truck, guided by a ground worker. The operator was standing on the ground using a remote control box that hung from his neck by a strap. He moved the boom into contact with an 11-kilovolt overhead power line and was electrocuted.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, CONCRETE TRUCK, E GI IA, BOOM, ELECTROCUTED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 106512189 Fatality Electric Shock Industrial truck and tractor equipment operators
2 106512197 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.