Accident Summary Nr: 170694632 - Truck driver killed by flying object during repair

Accident Summary Nr: 170694632 -- Report ID: 0950625 -- Event Date: 07/01/1994
Inspection NrDate OpenedSICNAICSEstablishment Name
12021188307/11/199417990Pmi

Abstract: On July 1, 1994, Employee #1, a trained, experienced truck driver, was transporting a modular home unit with a cab-over tractor with low-body trailer. He stopped on the roadside to examine the air brake system for a possible malfunction because of a loss of air pressure and dragging brakes. While he examined the system, the Air Dryer CR Brakemaster unit, model Turbo-2000, failed at the desiccant canister body-canister base plate interface when the crimp ring securing the body to the base plate failed. (The ring was not recovered.) The canister body flew off, striking Employee #1 in the head and killing him. The California Highway Patrol discovered Employee #1 at approximately 2:00 a.m. The reason for the canister body separation is unknown; however, the most probable cause is a malfunction of the air dryer unit, resulting in failure of the crimp ring, a sudden surge in operating pressure (approximately 120 psi is normal), and failure of the unload valve. The fatality was not reported by the employer, as required, but by Employee #1's brother on July 7, 1994.

Keywords: HEAD, BRAKE, WORK RULES, CONSTRUCTION, EQUIPMENT FAILURE, HIGH PRESSURE, STRUCK BY, FLYING OBJECT, TRUCK DRIVER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 120211883 Fatality Concussion Truck drivers, heavy

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close