Accident Summary Nr: 170566947 - Employee injures hand between clutches; dies of blood clot

Accident Summary Nr: 170566947 -- Report ID: 0552700 -- Event Date: 12/09/1996
Inspection NrDate OpenedSICNAICSEstablishment Name
30036492402/13/199716220Edward Kraemer And Sons,Inc.

Abstract: On December 9, 1996, Employee #1, a crane belt oiler, was working from the side platform of a crane. Because the weather was cold, she decided to get out of the wind and clean the crane's inner components. She opened the outer sliding door, then the inner swinging guard doors, exposing the crane's drums and clutches. She was cleaning with a rag and a spray bottle of mineral spirits when she apparently slipped, and her hand became wedged between two revolving clutches. She sustained serious injuries, and her hand was amputated two weeks later after failed attempts to save it. Employee #1 continued inpatient and outpatient treatment involving skin grafts until January 31, 1997, when she suffered a massive pulmonary thromboembolism (blood clot) that resulted in her death. Employee #1 died at home on the same day that she had been schedulked to have more surgery. All of the crane's guards were in place at the time of the accident,. Employee #1 had received training, and she held a Class B card in the operating engineers' union.

Keywords: BLOOD CLOT, ROTATING PARTS, AMPUTATED, CLEANING, SLIP, CONSTRUCTION, CAUGHT BETWEEN, HAND, PULMONARY EMBOLISM, CRANE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building New project or new addition $50,000 to $250,000 1 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 300364924 Fatality Amputation Operating engineers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Steel Erection Of Solid Web-Connecting
Fatality Cause: Caught in stationary equipment

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.