Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 170159818 - Employees burned in explosion in a confined space

Accident Summary Nr: 170159818 -- Report ID: 0950632 -- Event Date: 12/04/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
11999316012/04/199344930Sea Trec Enterprises Inc
Inspection NrDate OpenedSICNAICSEstablishment Name
11198878806/23/199332730Superior Ready Mix Concrete
Inspection NrDate OpenedSICNAICSEstablishment Name
11999316012/04/199344930Sea Trec Enterprises Inc

Abstract: At approximately 9:15 a.m. on December 4, 1993, Employees #1 and #2, a painter and his helper, were critically burned in an explosion while the painter was painting inside a poorly ventilated void on a newly refurbished naval landing craft. They were taken to the UCSD burn center. The fire pattern indicates that the blaze started inside the #5 void, which measured approximately 5 feet high by 6 feet long by 10 feet wide. Each of the 7 voids were interconnected to the engine room by circular ports about 18 inches in diameter. Employee #2 was tending lines at the entrance and Employee #1 was spray painting inside the voids with unbonded and ungrounded equipment and devices for more than an hour when the explosion occurred. The use of unapproved and non-intrinsically safe equipment and devices (i.e., spray gun, paint pot, extension light, and flashlight) inside a confined and poorly-ventilated space filled with toxic and flammable vapors inadvertently sparked the blaze and seriously burned Employees #1 and #2. The employer was found in violation of several T8CCR. Citations and penalties were issued.

Keywords: FLAMMABLE VAPORS, WORK RULES, EXPLOSION, PROCESS SAFETY, TOXIC FUMES, BURN, VENTILATION, CONFINED SPACE, FIRE, PAINT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 119993160 Hospitalized injury Burn/Scald(Heat) Painters, construction and maintenance
2 111988788 Occupation Not Listed
3 119993160 Hospitalized injury Burn/Scald(Heat) Helpers, construction trades

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close