Accident Summary Nr: 170159560 - One killed, one injured when struck by flying pressure plate

Accident Summary Nr: 170159560 -- Report ID: 0950632 -- Event Date: 11/11/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
11200882611/13/199035110Solar

Abstract: Employee #1 and a coworker were pressure-testing the seals around the shaft on a large Solar Turbines, Inc., compressor, model C505. Employee #1 had installed 1-ton temporary cover plates over the inlet and outlet ports of the compressor, using only 7 bolts on each plate instead of the 20 bolts each had holes for, and threading the bolts only 1/2 in. to 1 in. instead of 4 in. When the pressure reached over 100 psi, one pressure plate blew off, flying about 50 ft. Employee #1 was decapitated. The coworker sustained multiple hand fractures, was partially deafened, and has vision problems. Employee #2, who was setting up another unit for testing about 15 ft away, suffered shoulder bruises and lacerations. The compressor was located just outside a garage-like test cell where Employee #2 worked.

Keywords: COMPRESSOR, MAINTENANCE, SHOULDER, UNSECURED, WORK RULES, LACERATION, STRUCK BY, FLYING OBJECT, DECAPITATED, PRESSURE RELEASE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 112008826 Fatality Amputation Production inspectors, checkers and examiners
2 112008826 Non Hospitalized injury Bruise/Contus/Abras Production inspectors, checkers and examiners

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close