Accident Report Detail

Accident Summary Nr: 158206.015 - Employee is killed when struck by pallet

Accident Summary Nr: 158206.015 -- Report ID: 0418400 -- Event Date: 07/14/2023
Inspection NrDate OpenedSICNAICSEstablishment Name
1684221.01507/19/2023624210Golden Gourmet, Llc

Abstract: At 4:55 p.m. on July 14, 2023, an employee had just come on shift and was driving his forklift down the aisle in the dry storage, when he noticed a shelf on the steel storage rack with the horizontal load bearing cross beam dislodged. The employee stopped his forklift and dismounted to look and see if he could get the pallet off. He turned around to get his phone off of the forklift to take a picture, when the shelf collapsed, and he was struck and pinned against the side of his forklift by the pallet of prepackaged, individual servings of green beans (56 boxes at 18 pounds per box). The pallet weighed in excess of 1,000 pounds. The employee suffered a fractured ankle, lacerations to the knee and face, and multiple fractures throughout his face. The employee was killed.

Keywords: Aisle, Ankle, Collapse, Face, Forklift, Fracture, Knee, Laceration, Pallet, Pinned, Storage Rack, Struck By

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1684221.015 54 M Fatality Industrial truck and tractor equipment operators

Accident Summary Nr: 149928.015 - Employee is killed in fall on same level

Accident Summary Nr: 149928.015 -- Report ID: 0626300 -- Event Date: 09/22/2022
Inspection NrDate OpenedSICNAICSEstablishment Name
1624316.01509/23/2022337110Dck Manufacturing Llc

Abstract: At 10:15 a.m. on September 22, 2022, an employee was operating a BBQ grill next to a staircase in font of the building while coworkers were restacking slabs of synthetic marble nearby when the stack suddenly shifted and the slab rack collapsed. The slabs struck the staircase causing the employee to fall and hit her head against the metal staircase. The employee died due to a skull fracture and loss of blood.

Keywords: Bleeding, Blunt force, Blunt force trauma, Brain Bleed, Collapse, Concrete Slab, Contact, Fall, Fall On Same Level, Fracture, Head, Skull, Stack, Stair, Storage Rack

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 1624316.015 42 F Fatality

Accident Summary Nr: 142057.015 - Employee fractures shoulder in fall in freezer

Accident Summary Nr: 142057.015 -- Report ID: 0951510 -- Event Date: 12/02/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1569392.01512/06/2021424430Pint Size Hawaii Llc

Abstract: At 5:45 a.m. on December 2, 2021, an employee was pulling an order of ice cream from a shelf that was 16 feet off the ground of an industrial freezer when the support beam he stepped on gave way and he fell to the lower level. The employee was hospitalized to treat a left shoulder fracture.

Keywords: Beam, Blunt force, Blunt force trauma, Collapse, Fall, Fall From Elevation, Fracture, Freezer Compartment, Shoulder, Shoulder Bone, Storage Rack

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1569392.015 45 M Hospitalized injury Freight, stock and material handlers, n.e.c.

Accident Summary Nr: 131696.015 - One employee is killed and another employee is injured after

Accident Summary Nr: 131696.015 -- Report ID: 0728900 -- Event Date: 12/12/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1506467.01512/14/2020493120Smithfield Foods

Abstract: At 9:45 p.m. on December 12, 2020, Employee #1 was taking inventory of palletized boxes at the metal storage racks near Freezer #1. A Turret Truck was being operated in Freezer #1. The storage racks were not equipped with impact protection at the end of the aisles adjacent to the racking. The Turret Truck struck the upright of the racking, causing the racking to collapse and the pallets and boxes to fall, crushing Employee #1 and killing him. Employee #2 was also injured due to the collapse and was hospitalized.

Keywords: Collapse, Crushed, Falling Object, Forklift, Freezer Compartment, Industrial Truck, Material Handling, Pallet, Powered Industrial Vehicle, Storage Area, Storage Rack, Struck By, Underpinning, Warehouse

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1506467.015 38 M Hospitalized injury Industrial truck and tractor equipment operators
2 1506467.015 33 M Fatality Industrial truck and tractor equipment operators

Accident Summary Nr: 126938.015 - Employee sustains multiple injuries when crushed by collapsi

Accident Summary Nr: 126938.015 -- Report ID: 0352470 -- Event Date: 04/27/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1473484.01504/28/2020811310Advanced Equipment Company, Inc.

Abstract: At 9:20 a.m. on April 27, 20202, an employee and a coworker were repairing a commercial storage rack containing 14,000 pounds of spices. They used a jack system (Damotech Easy Lift C113 ) to jack the storage rack up to cut and remove the damaged part. The jack system, with a 30,000 pound capacity, slipped out causing the rack to collapse, injuring the employee. The jack slipped because a come-along strap was not used to secure the jack and prevent slipping as specified in the operations manual. The employee sustained multiple contusions, a burst/crushed L3 requiring fusion with rods and screws, and fractured left middle fingertip. He was hospitalized.

Keywords: Collapse, Contusion, Crushed, Falling Object, Fingertip, Fracture, Jack, Maintenance, Repair, Storage Rack, Strap, Unsecured, Vertebra

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1473484.015 47 M Hospitalized injury Installers And Repairers

Accident Summary Nr: 125453.015 - Employee suffers leg abrasions when storage rack collapses

Accident Summary Nr: 125453.015 -- Report ID: 0355112 -- Event Date: 02/10/2020
Inspection NrDate OpenedSICNAICSEstablishment Name
1462010.01502/10/2020926130Isle Of Wight County, Department Of Public Utilities

Abstract: At 12:00 noon on February 10, 2020, an employee was stacking PVC pipes onto a storage rack when the rack cracked and broke. The employee was struck by falling pipes and metal scrap materials. The employee suffered contusions and abrasions on his leg and was treated without hospitalization.

Keywords: Abrasion, Blunt force, Blunt force trauma, Collapse, Contusion, Falling Object, Leg, Pipe, Scrap Metal, Stack, Storage Rack, Struck By

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1462010.015 35 M Non Hospitalized injury Laborers, except construction

Accident Summary Nr: 108519.015 - Employee is struck and killed by collapsing storage rack

Accident Summary Nr: 108519.015 -- Report ID: 0950643 -- Event Date: 03/26/2018
Inspection NrDate OpenedSICNAICSEstablishment Name
1304647.01503/27/2018337920Sistemas Delfin Usa, Inc.

Abstract: At 11:55 a.m. on March 26, 2018, Employee #1 was using a Raymond stand-Up forklift to remove material from a cantilever rack storage system. During work, Employee #1 inadvertently backed into another racking system, causing it to collapse and fall onto Employee #1. Employee #1 suffered blunt force trauma to his abdomen and chest, and was killed.

Keywords: Abdomen, Backing Up, Chest, Collapse, Storage Rack, Struck By

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1304647.015 39 M Fatality Industrial truck and tractor equipment operators

Accident Summary Nr: 104323.015 - Employee is struck by falling pipes and fractures leg

Accident Summary Nr: 104323.015 -- Report ID: 0950632 -- Event Date: 03/07/2018
Inspection NrDate OpenedSICNAICSEstablishment Name
1305487.01503/29/2018238990Gbs Fence Co.

Abstract: At 12:45 p.m. on March 7, 2018, Employee #1, foreman for a fencing company's storage yard, was transferring fencing material from the 6.5-foot high forks of a forklift onto a storage rack. The material consisted of galvanized pipes measuring approximately 21 feet long. Employee #1 subsequently estimated he had placed pipes weighing approximately 660 pounds onto the storage rack. As he rolled another pipe onto the rack, the rack collapsed, and all the pipes previously placed on the rack fell, with some landing on Employee #1's right leg. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and treated for a fractured right tibia that required surgery.

Keywords: Aerial Lift, Construction, Falling Object, Fracture, Leg, Material Handling, Pipe, Storage Rack, Struck By, Structural Collapse

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1305487.015 57 M Hospitalized injury Construction laborers

Accident Summary Nr: 84013.015 - Employee is struck and killed when warehouse storage rack co

Accident Summary Nr: 84013.015 -- Report ID: 0355114 -- Event Date: 03/29/2016
Inspection NrDate OpenedSICNAICSEstablishment Name
1135906.01503/29/2016424490Reinhart Food Service, Llc.

Abstract: At 3:45 p.m. on March 29, 2016 an employee was pulling orders in warehouse when the storage racks in the warehouse collapsed, striking the employee with cases of frozen food products. The employee sustained blunt force trauma to head and neck due to the cases of frozen food products falling and striking the employee. The employee was killed.

Keywords: Collapse, Storage Rack, Struck By, Warehouse

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1135906.015 21 M Fatality Stock handlers and baggers

Accident Summary Nr: 200361780 - Employee Is Struck by Collapsed Shelving and Is Injured

Accident Summary Nr: 200361780 -- Report ID: 0453710 -- Event Date: 07/16/2013
Inspection NrDate OpenedSICNAICSEstablishment Name
31727537807/22/20135331452990Dolgencorp, Llc Dba Dollar General Store # 1832

Abstract: On July 16, 2013, Employee #1 was sorting product on a seven tier high shelving that was 60 ft in length. The shelving was located on the back wall of the store. While she was sorting the product, the shelving suddenly tipped over and fell on her, causing her to sustain strains and contusions. Emergency medical personnel were summoned. They arrived and transported Employee #1 by ambulance to a medical center, where she was treated and then released.

Keywords: COLLAPSE, UNSECURED, STORAGE RACK, STRUCK BY, CONTUSION, OVERTURN, UNSTABLE POSITION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 317275378 Non Hospitalized injury Strain/Sprain Occupation not reported

Accident Summary Nr: 201702677 - Worker Is Hospitalized Following Rack Collapse

Accident Summary Nr: 201702677 -- Report ID: 1054115 -- Event Date: 10/21/2008
Inspection NrDate OpenedSICNAICSEstablishment Name
31226333812/04/20082451321991Cmh Manufacturing West Inc

Abstract: At about 8:30 a.m. on October 21, 2008, Employee #1 of CMH Manufacturing West, Inc. was taking his break. He sat down on a storage rack holding mirrors and the rack collapsed after the legs of the rack failed.

Keywords: COLLAPSE, FALL, STORAGE RACK

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 312263338 Hospitalized injury Fracture Laborers, except construction

Accident Summary Nr: 202464822 - Employee Fractures Ankle When Rack Holding Steel Parts Falls

Accident Summary Nr: 202464822 -- Report ID: 0950643 -- Event Date: 02/27/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
31019665403/21/20073446332323Universal Iron Works, Inc

Abstract: On February 27, 2007, Employee #1 was working as a welder at a shop where structural metal products were fabricated. At the time of the accident, he was loading steel tubing and bars onto a four-level storage rack in the facility's production area. Employee #1's supervisor had assigned him to assist two other employees with loading various sized steel tubes and bars onto the storage rack. After loading for a while, one of the employees was told to go to the field, and a little while later the other employee was told by the supervisor to do something else, leaving Employee #1 to finish loading the steel tubes and bars by himself. He had only two more pieces to load and was placing one of them onto the second level of the storage rack, when the pieces began to fall off the rack. He was knocked to the floor, with some of the steel tubes and bars landing on his legs, leaving him unable to move. Other employees ran over to move the steel tubes and bars off his legs and pull him away. The storage rack had bent and collapsed, allowing the steel tubes to fall off. Employee #1's left ankle was fractured. He was taken by paramedics to Pacifica Hospital in Sun Valley, CA, where he had surgery. Two plates and seventeen pins were installed in his ankle. He was hospitalized for six days.

Keywords: FRACTURE, COLLAPSE, STEEL TUBE, METAL SHOP, OVERLOADED, WELDER, STORAGE RACK, STRUCK BY, FALLING OBJECT, ANKLE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 310196654 Hospitalized injury Fracture Welders and cutters

Accident Summary Nr: 202360574 - Storage Rack Collapses Injuring Retail Worker

Accident Summary Nr: 202360574 -- Report ID: 0352430 -- Event Date: 11/01/2006
Inspection NrDate OpenedSICNAICSEstablishment Name
31063181711/01/20065651448140Filene'S Basement, Inc.

Abstract: At approximately 2:47 p.m. on November 1, 2006, a salesperson walked into the stockroom at Filenes Basement, a discount-clothing store. She walked down a congested aisle, to an area where shoes were stored. She was in the southeast area of the stockroom when the steel pipe storage rack partially collapsed. When the rack system collapsed, various items fell and trapped the employee, pinning her right shoulder. Other coworkers heard the collapse and came to the employee's aid. The Fire Department was called and the trapped employee was freed within 20 minutes. She was taken to Greater Baltimore Medical Center, where she was hospitalized. She suffered bruises, sprains, and strains to her right arm, shoulder, and back. The storage rack system was overloaded with clothing, and it did not have enough anchorage points to support the load.

Keywords: CLOTHING, SHOULDER, COLLAPSE, OVERLOADED, STORAGE ROOM, BACK, STORAGE RACK, STRUCK BY, FALLING OBJECT, SPRAIN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 310631817 Hospitalized injury Strain/Sprain Sales workers, apparel

Accident Summary Nr: 202358560 - Employee Is Injured in Fall from Ladder

Accident Summary Nr: 202358560 -- Report ID: 0352450 -- Event Date: 09/04/2006
Inspection NrDate OpenedSICNAICSEstablishment Name
30967606209/06/20065311452111Sears Holding Corp.

Abstract: Employee #1 was retrieving a truck tire off the top rack of the tire storage racks, when the horizontal beam of the rack the tire was sitting on came loose. Employee #1 lost his balance and fell sideways off the 6-ft stair ladder to the floor. Employee #1 was taken to the hospital and treated for a sprained right ankle.

Keywords: COLLAPSE, LADDER, TRUCK, FALL, STORAGE RACK, STORAGE AREA, SPRAIN, ANKLE, TIRE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 309676062 Non Hospitalized injury Strain/Sprain Sales support occupations, n.e.c.

Accident Summary Nr: 201489135 - Two Employees Are Hurt When Shelves Collapse

Accident Summary Nr: 201489135 -- Report ID: 0950622 -- Event Date: 07/19/2006
Inspection NrDate OpenedSICNAICSEstablishment Name
30112623110/13/2006539945299099 Cent Store #218

Abstract: On July 19, 2006, Employees #1 and #2 were working at a general merchandise store, stocking shelves and performing janitorial duties such as cleaning the floor and the lower portions of shelves. Suddenly, an 80-foot section of shelving along with food products came crashing down, causing the two workers to receive head and neck injuries. Both workers sustained bruises, contusions, and abrasions to several parts of their bodies. They were treated at the scene by emergency medical personnel, transported to a hospital, and released after six hours. They were not hospitalized, but both employees underwent physical therapy.

Keywords: JANITOR, COLLAPSE, ABRASION, STORAGE RACK, STRUCK BY, FALLING OBJECT, CONTUSION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 301126231 Non Hospitalized injury Bruise/Contus/Abras Laborers, except construction
2 301126231 Non Hospitalized injury Bruise/Contus/Abras Laborers, except construction

Accident Summary Nr: 200623759 - Employee Is Killed When Storage Rack Collapses

Accident Summary Nr: 200623759 -- Report ID: 0454714 -- Event Date: 04/10/2006
Inspection NrDate OpenedSICNAICSEstablishment Name
30992450404/11/20065051423510Volunteer Wire Rope & Supply Company

Abstract: On April 10, 2006, Employee #1 was killed, when he was struck by a storage rack that collapsed at the Volunteer Wire Rope and Supply Company warehouse.

Keywords: COLLAPSE, WAREHOUSE, INDUSTRIAL TRUCK, STORAGE RACK, STRUCK BY

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 309924504 Fatality Other Industrial truck and tractor equipment operators

Accident Summary Nr: 200924314 - Employee Is Killed by Roll of Fabric When Rack Collapses

Accident Summary Nr: 200924314 -- Report ID: 0355117 -- Event Date: 03/14/2006
Inspection NrDate OpenedSICNAICSEstablishment Name
30995657103/14/20062262313311B.G.F. Industries

Abstract: On March 14, 2006, Employee #1 was working in the warehouse of a fabric mill. A section of steel racks approximately 90 feet long collapsed, causing a 1,500-pound roll of cloth to strike Employee #1, crushing him in his head and upper torso. He was pronounced dead at the scene.

Keywords: HEAD, COLLAPSE, WAREHOUSE, TORSO, CRUSHED, TEXTILE PRODUCTION, STORAGE RACK, TEXTILE, FALLING OBJECT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 309956571 Fatality Other Occupation not reported

Accident Summary Nr: 200612026 - Employees Are Injured in Rack Collapse

Accident Summary Nr: 200612026 -- Report ID: 0111700 -- Event Date: 11/15/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
30695284711/15/20051711238220Ouellette Plumbing & Heating Corp.

Abstract: On November 15, 2005, Employees #1 through #6 were loading a Unistrut rack with copper pipe of varying sizes. The rack collapsed Employee #1, who was then hospitalized with fractures. Employees #2 trough #6 sustained various injuries during the rescue of Employee #1. The rack had been improperly constructed in three ways: (1) single through-bolts were used to assemble some of the horizontal and vertical members within the rack, instead of "T" or gusset connections, as specified by the rack component manufacturer; using the single bolts allowed the connections to rotate around the bolt, (2) the horizontal braces were connected with single bolts, instead of "T" or gusset connections, as specified by the rack component manufacturer; using the single bolts allowed the connections to rotate around the bolt, and (3) diagonal braces were not used to stabilize the frames.

Keywords: COLLAPSE, EQUIPMENT FAILURE, BOLT, BRACE, PIPE, STORAGE RACK, STRUCK BY, STORAGE AREA
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other building New project or new addition $5,000,000 to $20,000,000 4

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 306952847 Non Hospitalized injury Bruise/Contus/Abras Occupation not reported
2 306952847 Non Hospitalized injury Strain/Sprain Occupation not reported
3 306952847 Non Hospitalized injury Bruise/Contus/Abras Occupation not reported
4 306952847 Non Hospitalized injury Strain/Sprain Occupation not reported
5 306952847 Hospitalized injury Fracture Occupation not reported
6 306952847 Non Hospitalized injury Bruise/Contus/Abras Occupation not reported

Accident Summary Nr: 201988946 - Employee Killed When Racks Collapse

Accident Summary Nr: 201988946 -- Report ID: 0950411 -- Event Date: 02/13/2003
Inspection NrDate OpenedSICNAICSEstablishment Name
30639233302/13/20034225493110Starr Distribution Services Corporation

Abstract: Employee #1 was loading and unloading pallets of merchandise onto a storage rack when the loaded racks on the opposite side of the aisle collapsed. Employee #1 was caught in the racks and crushed by the material stored on the racks. Employee #1 was killed.

Keywords: ASPHYXIATED, COLLAPSE, WAREHOUSE, CAUGHT BETWEEN, CRUSHED, STORAGE RACK

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 306392333 Fatality Asphyxia Occupation not reported

Accident Summary Nr: 201503356 - Employee Is Injured in Fall When Damaged Rack Fails

Accident Summary Nr: 201503356 -- Report ID: 0950614 -- Event Date: 07/26/2002
Inspection NrDate OpenedSICNAICSEstablishment Name
30113369008/06/200242250Winward Silks

Abstract: On July 26, 2002, Employee #1, a warehouseman who was obese (weighing approximately 350 pounds), was elevated on an order picker. As he placed his right foot on a support beam of a metal storage rack structure, the beam failed, and he fell 12 ft 9 in. to grade. Employee #1 was hospitalized for surgical repair of the separation of his right acromioclavicular joint. The investigation determined that employee was not provided personal fall restraint or personal fall arrest protection equipment. Examination of the metal rack system determined that the retaining pin holes on one of the vertical members had damage at the 12 ft 9 in. and 12 ft 7 in. elevations. The rack system was inspected by the manufacturer, who determined that the damage was the result of the support beam being caught by forks and pulled outward. This damage and the live load of Employee #1 on the beam caused the left post retaining pins to pop out and the beam to fall.

Keywords: BEAM, SHOULDER, COLLAPSE, PIN, INDUSTRIAL TRUCK, FALL, FALL PROTECTION, STORAGE RACK, ELEVATED WORK PLAT, STORAGE AREA

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 301133690 Hospitalized injury Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.