Accident Report Detail
Accident Summary Nr: 14559173 - Employee dies of asphyxia during trench cave-in
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 114624018 | 09/18/1990 | 1623 | 0 | Homesteader Construction, Inc. |
Abstract: At approximately 8:40 a.m. on September 17, 1990, Employee #1 was in a trench that was one block long by 4 ft wide by 8 ft deep to connect a 6 in. water line to a 10 in. water line. The walls of the trench were vertical except for the last 1 1/2 ft. The spoil pile was next to the edge of the trench. The west side of the trench caved in, burying Employee #1 above his knees. Two coworkers were trying to dig him out when the west side caved in again, completely burying Employee #1 and buring the coworkers to their waists. Employee #1 died of asphyxia.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 114624018 | Fatality | Asphyxia | Construction laborers |