Accident Summary Nr: 14212609 - Impaled by 30ft Mandrell
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 103247623 | 03/26/1987 | 3089 | 0 | Smith Fiberglass Products, Inc. |
Abstract: On March 26, 1987, Employee #1 was operating a fiberglass pipe stripping machine. The fiberglass pipe is held in place at the head of the stripper while a carriage that has jaws attached internally to the mandrel pulls it out. The carriage normally contacts various sensors at the rear to slow it, stop it and to inform lift arms to lift the mandrel up to a rack. The lift arm did not function and the carriage started back pushing the mandrel rack along with the pipe. Employee #1 leaned over in a space 14.5 inches wide between the stripper and conveyor to pick up a half section of split pushing that fell. The returning mandrel caught Employee #1 between the two pieces of machinery and struck him under the left shoulder blade, penetrated his chest and then exited out of his mouth. The puncture caused severe enough injury that Employee #1 was killed.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 103247623 | Fatality | Puncture | Occupation not reported |
Translate