Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 141449.015 - Employee incurs multiple injuries in fall through scaffold p

Accident Summary Nr: 141449.015 -- Report ID: 0728900 -- Event Date: 11/19/2021
Inspection NrDate OpenedSICNAICSEstablishment Name
1565637.01511/22/2021926130Brandsafway, Llc

Abstract: At 11:15 a.m. on November 19, 2021, an employee was walking on a temporary aluminum plate working surface inside the boiler during scaffolding removal. One of the temporary aluminum plates failed, and the employee fell through the opening to the concrete floor. The employee was hospitalized to treat a broken pelvis, punctured lung, and broken wrist.

Keywords: Boiler, Broken Bone, Concrete Floor, Fall, Fall From Elevation, Floor Opening, Lung, Pelvis, Puncture Wound, Removal, Scaffold, Walking Surface, Wrist
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Powerplant Other  

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1565637.015 23 M Hospitalized injury Construction laborers Distance of Fall: 20 feet
Worker Height Above Ground/Floor: 20 feet
Cause: Other Activities-Installing Ornamental And Archite
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close