Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 117886.015 - Employee amputates fingers in chute of a stud mill machine

Accident Summary Nr: 117886.015 -- Report ID: 0625700 -- Event Date: 07/07/2019
Inspection NrDate OpenedSICNAICSEstablishment Name
1414780.01507/10/2019321212Boise Cascade

Abstract: At 1:15 p.m. on July 7, 2019, an employee stuck his left hand inside a clogged studmill machine chute which had not been locked out in order to clean the chute out. The employee struck the blades inside the chute with his hand. The employee amputated his index and middle fingers and partially amputated his thumb, requiring hospitalization.

Keywords: Amputated, Amputation, Blade, Caught In, Finger, Fingertip, Hand, Lockout, Lockout/Tagout, Lumber, Machine operator, Material Handling, Milling Machine, Partial Amputation, Point Of Operation, Sawmill, Thumb, Wood Board

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1414780.015 59 M Hospitalized injury Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.